text.skipToContent text.skipToNavigation

P1PY208 Laser Distance Sensor Time of Flight

Available from stock
The sensors function in accordance with the principle of transit time measurement with laser class 1. wintec with Dynamic Sensitivity technology (DS) enables previously unattainable reception sensitivity even with very weak signals. As a result, the sensors have a large working range of up to 10 m and can reliably detect dark or shiny objects even at extreme angles. wintec also works very reliably in adverse ambient conditions, such as those caused by ambient light or contamination. Extensive condition monitoring functions additionally enable predictive maintenance and trouble-free operation. Settings are entered via the easy-to-read OLED display or via Bluetooth using the weCon app.

Optical Data

Working Range 0 ... 10,000 mm
Measuring Range 50 ... 10,000 mm
Reproducibility maximum 3 mm*
Linearity Deviation 10 mm*
Light Source Laser (red)
Wavelength 660 nm
Service Life (T = +25 °C) 100,000 h
Laser Class (EN 60825-1) 1
Beam Divergence < 2 mrad
Max. Ambient Light 100,000 Lux
Light Spot Diameter see Table 1
Reflector required no

Electrical Data

Supply Voltage 18 ... 30 V DC
Current Consumption (Ub = 24 V) < 60 mA
Measuring Rate 100 /s*
Measuring Rate (max.) 500 /s*
Temperature Drift < 0.4 mm/K
Temperature Range -40 ... 50 °C**
Analog Output 4...20 mA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Interface IO-Link V1.1.3
Baud Rate COM3
Protection Class III
FDA Accession Number 2412451-000

Mechanical Data

Setting Method (OLED)/Bluetooth menu
Housing Material Plastic, ABS
Optic Cover Plastic, PMMA
Degree of Protection IP67
Connection M12 × 1; 4/5-pin
Weight 45 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 353.85 a

Output

PNP NO yes
Analog Output yes
IO-Link yes

Adjustable parameters

Output Error Output
Warning output
Other parameters Off-delay
On-delay
Sensitivity
Filter
Unit of measure
Measuring mode
Emitted light
Sensor localization
Teach mode
All other parameters can be found in the product documentation.

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf
* Depends on mode, see table 2
** At max. 10,000 lux ambient light and min. 500 ohm load at analog output

Table 1

Working Distance 0 m 5 m 10 m
Light Spot Diameter 5 mm 10 mm 15 mm

Table 2

Connection Diagram

- = supply voltage 0 V
+ = supply voltage +
E/A1 = programmable input/output / IO-Link
E3 = input
O = analog output

Ctrl. Panel

68 = supply voltage indicator
5a = Switching Status Indicator, A1
20 = Enter key
60 = display
7c = Analog Output Indicator, O

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
1 = Transmitter Diode 2 = Receiver Diode Screw M4 = 0.5 Nm

Complementary Products

  • IO-Link Master
  • Software
  • Protective Screen
Initial start-up instructions
Operating instructions
Product description file
Product description file
wenglor-P1PY208-20241204-IODD1.1.zip
Interface protocol
Interface protocol
Interface_Protocol_IO-Link_Parameter_Process_Data_P1PY2xx_P1PX2xx.pdf
Declarations of Conformity / Approvals

Product Highlights

This area provides a deeper insight into this product world. All information about new product series as well as tutorials, templates and much more are combined here and are clearly prepared – tangible, understandable and traceable. Everything at a glance.
Product Comparison