text.skipToContent text.skipToNavigation

Industrial Communication. Stay Connected.

wen­glor offre una so­lu­zio­ne di si­ste­ma IO-​Link com­ple­ta, com­po­sta da IO-​Link Ma­ster, hub IO-​Link e con­ver­ti­to­re IO-​Link nonché sen­so­ri con IO-​Link. Que­sta tec­no­lo­gia con­sen­te una co­mu­ni­ca­zio­ne di­ret­ta e senza in­ter­ru­zio­ni tra mac­chi­ne e si­ste­mi di con­trol­lo, con­sen­ten­do il mo­ni­to­rag­gio e l’ot­ti­miz­za­zio­ne dei pro­ces­si. IO-​Link è si­no­ni­mo di tra­sfe­ri­men­to ra­pi­do dei dati, per­so­na­liz­za­zio­ne fles­si­bi­le e fa­ci­le in­te­gra­zio­ne nelle reti esi­sten­ti.

Be­ne­fi­ci a colpo d’oc­chio.

Messa in fun­zio­ne sem­pli­ce
So­sti­tu­zio­ne ra­pi­da del sen­so­re
Con­di­tion Mo­ni­to­ring
Più va­lo­ri mi­su­ra­ti per ap­pa­rec­chio

Ar­chi­tet­tu­ra del si­ste­ma IO-​Link

L’ar­chi­tet­tu­ra del si­ste­ma IO-​Link si basa sul nodo cen­tra­le IO-​Link ma­ster. Que­sto con­sen­te una co­mu­ni­ca­zio­ne bi­di­re­zio­na­le tra sen­so­ri, at­tua­to­ri e il si­ste­ma di con­trol­lo, che funge da unità di cal­co­lo dell’in­te­ro si­ste­ma. Tra­mi­te l’IO-​Link ma­ster è pos­si­bi­le col­le­ga­re sen­so­ri IO-​Link, sen­so­ri a com­mu­ta­zio­ne di­gi­ta­le (fino a 16 per hub tra­mi­te una sola porta sul ma­ster) nonché sen­so­ri ana­lo­gi­ci i cui se­gna­li ven­go­no con­ver­ti­ti con l’au­si­lio di un con­ver­ti­to­re ana­lo­gi­co. L’in­te­gra­zio­ne av­vie­ne in­di­pen­den­te­men­te dal pro­dut­to­re e dal sen­so­re tra­mi­te un solo in­gres­so/input sul si­ste­ma di con­trol­lo. Inol­tre, l’IO-​Link ma­ster con­sen­te il mo­ni­to­rag­gio del si­ste­ma in­di­pen­den­te­men­te dalla po­si­zio­ne gra­zie all’ac­ces­so al cloud ed è quin­di pron­to per l’IIoT.

So­lu­zio­ne di si­ste­ma IO-​Link di wen­glor

La gamma di pro­dot­ti IO-​Link offre un’ampia scel­ta di sen­so­ri e ac­ces­so­ri IO-​Link, adat­ta­ti in modo ot­ti­ma­le alle mol­te­pli­ci esi­gen­ze dell’in­du­stria. Tra que­sti vi sono sen­so­ri op­to­e­let­tro­ni­ci, sen­so­ri a ul­tra­suo­ni, sen­so­ri in­dut­ti­vi, sen­so­ri per flui­di, nonché cavi di col­le­ga­men­to spe­cia­li e so­lu­zio­ni soft­ware.

“wen­glor offre una so­lu­zio­ne del si­ste­ma com­ple­ta per si­ste­mi IO-​Link che copre tutti i com­po­nen­ti ne­ces­sa­ri, dal ma­ster e dai con­ver­ti­to­ri ana­lo­gi­ci ai sen­so­ri IO-​Link.

Nel set­to­re dell’au­to­ma­zio­ne, l'ef­fi­cien­za e la flessibilità sono es­sen­zia­li. wen­glor com­pren­de per­fet­ta­men­te que­ste esi­gen­ze e vi sup­por­ta con un port­fo­lio di pro­dot­ti IO-​Link per­so­na­liz­za­to come part­ner af­fi­da­bi­le nell’ot­ti­miz­za­zio­ne dei vo­stri pro­ces­si."

Maik Eben­dorff, esper­to di ven­di­ta pro­dot­ti Sen­so­ri

Portfolio IO-Link
Cavi di collegamento speciale
Sensori a ultrasuoni con IO-Link
Sensori optoelettronici con IO-Link
Sensori induttivi con IO-Link
Software wTeach
Software per IO-Link master
Sensori per fluidi con IO-Link

IO-​Link Pro­duct Va­rie­ty

IO-​Link Ma­ster for Cloud-​Based Sy­stems

  • In­de­pen­dent in­te­gra­tion of sen­sors and ac­tua­tors from dif­fe­rent ma­nu­fac­tu­rers

  • Quick re­pla­ce­ment of sen­sors and ac­tua­tors wi­thout re­peat ma­nual pa­ra­me­te­ri­za­tion 

  • In­te­gra­tion of IODD on board and web ser­vers with IODD in­ter­pre­ter for easy pa­ra­me­te­ri­za­tion and data trans­fer

  • Sup­ports the most com­mon In­du­strial Ether­net com­mu­ni­ca­tion pro­to­cols with high fle­xi­bi­li­ty wi­thin the pro­duct range and va­rious port usage op­tions (e.g. Class A or Class B, di­gi­tal input or out­put, IO-​Link port)


From Sen­sor to Cloud – IIoT-​Ready

Sen­sor and Ac­tua­tor Level

  • Re­cor­ding of phy­si­cal pa­ra­me­ters (e.g. tem­pe­ra­tu­re, pres­su­re, po­si­tion)

  • Data ac­qui­si­tion and con­ver­sion into di­gi­tal si­gnals

  • Ma­chi­ne con­di­tion mo­ni­to­ring

wTeach Soft­ware for IO-​Link Sen­sors

  • Quick and easy con­fi­gu­ra­tion of sen­sor pa­ra­me­ters

  • De­cen­tra­li­zed, off-​site pa­ra­me­ters con­fi­gu­ra­tion, mo­ni­to­ring and dia­gno­sis of sen­sors

  • Com­pa­ti­ble with IO-​Link ver­sions 1.0 and 1.1


IO-​Link Hubs for Ef­fi­cient Con­nec­tions

  • Re­cor­ding of di­gi­tal swit­ching si­gnals and tran­smis­sion to the IO-​Link ma­ster

  • Re­duc­tion of con­trol in­pu­ts

  • Mi­ni­mi­zed ca­bling ef­fort as up to 16 DIOs (di­gi­tal in­pu­ts and out­pu­ts) are bund­led on one hub


IO-​Link Ana­log Con­ver­ter for In­te­gra­tion of Sen­sors with Ana­log In­ter­fa­ce

  • Ac­qui­si­tion of ana­log input si­gnals and con­ver­sion to di­gi­tal IO-​Link si­gnals

  • Uses the ad­van­ta­ges of IO-​Link wi­thout the need for sen­sor re­pla­ce­ment

  • Sup­port of mixed en­vi­ron­men­ts with IO-​Link de­vi­ces, swit­ching de­vi­ces and ana­log de­vi­ces


Use Cases with IO-​Link Pro­duc­ts

Fle­xi­ble Sen­sor Pa­ra­me­te­ri­za­tion

  • In­crea­sed ef­fi­cien­cy due to sim­ple pa­ra­me­te­ri­za­tion when chan­ging ma­te­rial du­ring ope­ra­tion

  • Re­duc­tion of do­wn­ti­mes due to au­to­ma­tic adop­tion of the sto­red sen­sor pa­ra­me­ters when the sen­sor is re­pla­ced

Di­gi­ta­li­za­tion of Ana­log Si­gnals

  • No loss of ac­cu­ra­cy due to mul­ti­ple data con­ver­sion

  • Process-​reliable data tran­smis­sion with high elec­tro­ma­gne­tic com­pa­ti­bi­li­ty

  • In­sen­si­ti­ve to EMC in­fluen­ces due to di­gi­tal pro­cess value tran­smis­sion

Decentralized Structure

Plug & Play with Data Sto­ra­ge

  • Sen­sor pa­ra­me­ters are sto­red and au­to­ma­ti­cal­ly trans­fer­red when the sen­sor is re­pla­ced

  • Fast and error-​free re­pla­ce­ment thanks to au­to­ma­tic iden­ti­fi­ca­tion

  • Same pa­ra­me­te­ri­za­tion and op­ti­cal axis after sen­sor chan­ge with PNG//smart sen­sors

Chan­ging the For­mat

  • Fle­xi­ble adap­ta­tion to dif­fe­rent bat­ches for ef­fi­cient pro­duc­tion with va­ry­ing ma­te­rials and pro­duct sizes

  • Seam­less adap­ta­tion and mi­ni­mal do­wn­ti­mes due to sim­ple pa­ra­me­te­ri­za­tion when chan­ging the pro­gram of the IO-​Link pro­duc­ts

Interference-​Free Com­mu­ni­ca­tion

  • Process-​reliable data tran­smis­sion th­rou­gh high elec­tro­ma­gne­tic com­pa­ti­bi­li­ty

  • Use of un­shiel­ded stan­dard ca­bles for IO-​Link

Pro­duct Over­view

In­ter­fa­ce Spe­cial fea­tu­re Num­ber of IO ports
EP0L001 Ether­Net/IP Mul­ti­pro­to­col 8
EP8P001 PRO­FI­NET IIoT-​capable, IODD on board 8
EP8E001 Ether­Net/IP™ IIoT-​capable 8
EP8C001 Ether­CAT IIoT-​capable 8
Confronto dei prodotti