These ultrasonic sensors evaluate the sound reflected from the object. They can detect almost any object and are especially well suited for monitoring fill levels of liquids and bulk goods and for detecting transparent objects. The sensor detects objects regardless of material, state of matter, color or degree of transparency. The graphical display is menu-guided for easy setup of the sensors. The IO-Link interface makes parametrization and diagnosis quick and easy. The sensor can only be used in reflex mode operation.

Ultrasonic Data

Working Range 300 ... 6,000 mm
Measuring Range 5,700 mm
Reproducibility maximum 5 mm
Linearity Deviation 20 mm
Resolution 1 mm
Ultrasonic Frequency 75 kHz
Opening Angle < 14 °
Service Life (T = +25 °C) 100,000 h
Switching Hysteresis 30 mm

Electrical Data

Supply Voltage 18 ... 30 V DC
Current Consumption (Ub = 24 V) < 50 mA
Switching Frequency 1.5 Hz
Response Time  < 334 ms
Temperature Range -30 ... 60 °C
Number of Switching Outputs 2
Switching Output Voltage Drop < 2.5 V
PNP Switching Output/Switching Current 100 mA
Analog Output 4...20 mA
Synchronous Mode up to 40 sensors
Multiplex Mode up to 16 sensors
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Interface IO-Link V1.0
Protection Class III

Mechanical Data

Setting Method Menu (OLED)
Housing Material Epoxy resin/glass bubble mixture
Plastic, PBT
Plastic, PU
Silicone
Sensing face Plastic, ABS
Degree of Protection IP67
Connection M12 × 1; 4/5-pin
Weight 248 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 493.35 a

Function

Selectable menu language yes
Password Protection yes

Output

Error Output yes
PNP NO yes
Analog Output yes
IO-Link yes

Adjustable parameters

Analog output 4...20 mA
0...10 V
Output Error Output
PNP
Circuit NC
NO
NC/NO
Other parameters Filter
Multiplex mode
Adjustable sonic cone
Synchronous mode
Teach mode
All other parameters can be found in the product documentation.

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf
Display brightness may decrease with age. This does not result in any impairment of the sensor function.

Connection Diagram

Characteristic response curve

Characteristic curves show the position of the center or the front edge of the measured object (100 × 100 mm plate) at the time of switching.
Ob = Object
Sc = Sonic cone width
Standard sonic cone (center of the measured object)
Extra-narrow sonic cone (center of the measured object)
Standard sonic cone (front edge of the measured object)
Characteristic response curve
Characteristic curves show the position of the center or the front edge of the measured object (Ø 25 mm rod) at the time of switching.
Ob = Object
Sc = Sonic cone width
Standard sonic cone (center of the measured object)
Extra-narrow sonic cone (center of the measured object)

Ctrl. Panel

60 = display
20 = Enter key
22 = Up key
23 = Down key

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
1 = Sensing Face Screw M3 = 0,5 Nm

Complementary Products

  • IO-Link Master
  • PNP-NPN Converter BG2V1P-N-2M
  • Analog Evaluation Unit AW02
  • Software
Initial start-up instructions
Operating instructions
Product description file
Product description file
IODD_UMS603U035_V1.0.1.zip
Interface protocol
Interface protocol
Interface_Protocol_IO-Link_Parameter_Process_Data_UMSxxxU035.pdf
Declarations of Conformity / Approvals
Product certificates
Product certificates
UMS_IO-Link_V1.0_Manufacturer_declaration.pdf

Product Highlights

This area provides a deeper insight into this product world. All information about new product series as well as tutorials, templates and much more are combined here and are clearly prepared – tangible, understandable and traceable. Everything at a glance.
Product Comparison