text.skipToContent text.skipToNavigation

OCP801H0180 Laser Distance Sensor Triangulation

Available from stock
These sensors work with a high-resolution CMOS line and DSP technology and determine distance using angular measurement. As a result, material, color and brightness related measurement differences are virtually eliminated. Integrated analogue output can be configured for voltage 0...10 V (10...0 V) or current 4...20 mA (20...4 mA).

Optical Data

Working Range 30 ... 80 mm
Measuring Range 50 mm
Resolution 8 µm
Resolution (Speed-Mode) 12 µm
Linearity 0.1 %
Linearity (Speed-Mode) 0.2 %
Linearity Deviation 50 µm
Light Source Laser (red)
Wavelength 660 nm
Service Life (T = +25 °C) 100,000 h
Laser Class (EN 60825-1) 1
Max. Ambient Light 10,000 Lux
Light Spot Diameter see Table 1

Electrical Data

Supply Voltage 18 ... 30 V DC
Current Consumption (Ub = 24 V) < 80 mA
Measuring Rate 1,000 /s
Measuring Rate (Resolution-Mode) 500 /s
Response Time 1,000 µs
Response Time (Resolution Mode) < 2,000 µs
Temperature Drift < 5 µm/K
Temperature Range -25 ... 50 °C
Analog Output 0...10 V
Load Current Voltage Output < 1 mA
Current Output Load Resistance < 500 Ohm
Interface RS-232
Baud Rate 38,400 Bd
Protection Class III
FDA Accession Number 1120734-000

Mechanical Data

Setting Method Teach-In
Housing Material Plastic, ABS
Plastic, PC
Optic Cover Plastic, PMMA
Degree of Protection IP67
Connection M12 × 1; 8-pin
Weight 45 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 713.97 a

Output

Error Output yes
Analog Output yes
RS-232 Interface yes

Adjustable parameters

Analog output 0...10 V
4...20 mA
Other parameters Scale analog output
Exposure time
Filter
Resolution mode
Emitted light
Speed mode
All other parameters can be found in the product documentation.

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf

Table 1

Working Distance 30 mm 80 mm
Spot Size 0,4 × 0,8 mm 0,7 × 1,4 mm

Connection Diagram

Output Graph

c = Measuring Range
a = Analog Voltage Output

Ctrl. Panel

03 = Error Indicator
07 = Selector Switch
12 = Analog Output Indicator
24 = Plus Button
25 = Minus Button
63 = Analog Output Current Indicator

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
1 = Transmitter Diode 2 = Receiver Diode Screw M4 = 0.5 Nm

Complementary Products

  • Analog Evaluation Unit AW02
  • Interface Cable S232W3
  • Protective Housing ZSV-0x-01
  • Set Protective Housing ZSP-NN-02
  • Fieldbus Gateway ZAGxxxN01, EPGG001
  • Software
Product Comparison