text.skipToContent text.skipToNavigation

FX5Q101 Sensor de presión 2 × salidas analógicas

Usually ready to ship in 7 days after order is received.
Los sensores de presión weFlux2 miden la presión relativa de cualquier medio que se encuentre en sistemas cerrados. La presión aplicada a un sensor de presión se convierte en una señal electrónica. Las salidas analógicas proporcionan una lectura de presión y temperatura entre 4…20 mA.

Sensor-specific data

Measuring Range -1 ... 10 bar
Measurement Type relative
Maximum overload pressure 20 bar
Bursting pressure 30 bar
Medium Liquids, gases
Temperature Measurement Range -40 ... 125 °C
Response time (t90) Temp < 1 s
Pressure response time (t90) < 10 ms
Temperature Measurement Accuracy < ± 1 °C
Measuring error (total)  ± 0.5 %
Hysteresis  < ± 0.1 %
Linearity Deviation  < ± 0.5 %
Zero-point error < ± 0.1 %
Repeat Accuracy < ± 0.1 %
Temperature coefficient zero-point <± 0,05% /10K
Temperature coefficient range <± 0,05% /10K

Environmental conditions

Temperature of medium -40 ... 125 °C**
Ambient temperature -25 ... 80 °C
Storage temperature -25 ... 80 °C
EMC DIN EN 61326-2-3
Shock resistance per DIN IEC 68-2-27 50 g / 11 ms
Vibration resistance per DIN IEC 60068-2-6 10 g (10...2000 Hz)

Electrical Data

Supply Voltage 12 ... 32 V DC
Current Consumption (Ub = 24 V) < 15 mA
Number of analog outputs 2
Analog Output 4...20 mA
Signal source Pressure
Temperature
Resolution  > 11 bit
Current Output Load Resistance < 500 Ohm
Short Circuit Protection yes
Reverse Polarity Protection yes
Protection Class III

Mechanical Data

Sensor element Ceramic membrane
Housing Material Stainless steel, V4A (1.4404/316L)
Material in contact with media Stainless steel, V4A (1.4404 / 316L)
Rubber, FKM
Ceramic
Degree of Protection IP65 *
Connection M12 × 1; 4-pin
Process Connection G3/4"; front
Seal material Fluororubber, FKM
Weight 196 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 1,157.11 a

Output

Analog Output yes

Normas y certificados

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf
* sin certificado UL ** Sensores aptos para temperaturas del fluido de hasta 125 °C. Durante el montaje, asegúrese de que el entorno refrigere suficientemente la carcasa del sensor.

Connection Diagram

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
B_SYM_SCHLUESSEL_27.pdf Wrench Size
Product Comparison
Any questions?
Contact us!