text.skipToContent text.skipToNavigation

P1PM103 Reflex Light Barrier

Available from stock
The reflex light barriers work with red light and detect objects both via the intensity of the backscattered light and via the distance to a previously taught-in reference background. Thanks to the combined detection principle, the sensors are suitable for contactless object detection without a reflector, regardless of color, shape or surface. Due to their large range, reflex light barriers enable ejection and presence check applications as well as object detection on wide feed belts. The IO-Link interface can be used to configure reflex light barriers (PNP/NPN, NC/NO, teach-in mode) as well as for reading out switching statuses.

Optical Data

Range 1,000 mm
Reference Background White, 90% remission
Switching Hysteresis  < 5 %
Light Source Red Light
Service Life (T = +25 °C) 100,000 h
Max. Ambient Light 10,000 Lux
Light Spot Diameter see Table 1
Two-Lens Optic yes

Electrical Data

Supply Voltage 15 ... 30 V DC
Supply Voltage with IO-Link 18 ... 30 V DC
Current Consumption (Ub = 24 V) < 30 mA
Switching Frequency 900 Hz
Switching Frequency (interference-free mode) 450 Hz
Response Time 0.6 ms
Response time (interference-free mode) 1.1 ms
Temperature Drift < 10 %
Temperature Range -25 ... 60 °C
Switching Output Voltage Drop < 2 V
PNP Switching Output/Switching Current 100 mA
Residual Current Switching Output < 50 µA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Lockable yes
Teach Mode moving background
Interface IO-Link V1.1
IO-Link Version 1.1
Protection Class III

Mechanical Data

Setting Method Teach-In
Housing Material Plastic, ABS/PC
Degree of Protection IP67/IP68
Connection M12 × 1; 4-pin
Optic Cover Plastic, PMMA
Weight 35 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 803.65 a

Output

PNP NO yes
External teach-in input yes
IO-Link yes

Adjustable parameters

Output Push-pull
NPN
PNP
Circuit NC
NC+NO
NO
Other parameters Off-delay
On-delay
Dynamic readjustment
Error output
Filter
Hysteresis
Emitted light
Teach mode
All other parameters can be found in the product documentation.

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf

Table 1

Range 100 mm 500 mm 1000 mm
Light Spot Diameter 16 mm 22 mm 33 mm

Connection Diagram

Ctrl. Panel

06 = Teach Button
30 = Switching Status/Contamination Warning
68 = supply voltage indicator

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
1 = Transmitter Diode 2 = Receiver Diode 3 = Wrench Size 7 Screw M4 = 0.5 Nm

Reflector data

white (90 %) 0.1 ... 1 m
grey (18 %) 0.1 ... 0.7 m
black (6 %) 0.1 ... 0.45 m
Stainless Steel 0.1 ... 1 m

Complementary Products

  • Set Protective Housing Z1PS001
  • IO-Link Master
  • Software
Initial start-up instructions
Operating instructions
Product description file
Product description file
wenglor-P1PM103-20230830-IODD1.1.zip
Interface protocol
Interface protocol
Interface_Protocol_IO-Link_Parameter_Process_Data_P1PMxxx.pdf
Declarations of Conformity / Approvals

Product Highlights

This area provides a deeper insight into this product world. All information about new product series as well as tutorials, templates and much more are combined here and are clearly prepared – tangible, understandable and traceable. Everything at a glance.
Product Comparison