text.skipToContent text.skipToNavigation

X1TA100QXT3 Laser Distance Sensor Time of Flight

Available from stock
These sensors have scratch-resistant optics and the emitted light can be switched off. They use the transit time measurement principle to measure the distance between the sensor and the object. Using a suitable reflector at the object, a highly accurate position measurement at large distances is also possible. The configurations are selected using a menu and can be protected by a password.

Optical Data

Working Range 0.1 ... 10.2 m
Analog Working Range 0.2 ... 10.2 m
Measuring Range 10 m
Reference Reflector/Reflector Foil RF508
Resolution 2 ... 6 mm
Linearity 0.5 %
Linearity Deviation 50 mm
Switching Hysteresis 3 ... 20 mm
Light Source Laser (red)
Wavelength 660 nm
Service Life (T = +25 °C) 100,000 h
Laser Class (EN 60825-1) 1
Max. Ambient Light 10,000 Lux
Beam Divergence < 2 mrad
Reflector required yes

Electrical Data

Supply Voltage 18 ... 30 V DC
Current Consumption (Ub = 24 V) < 100 mA
Switching Frequency 50 Hz
Measuring Rate 1 ... 100 /s
Response Time 10 ... 200 ms
On-/Off-Delay 0 ... 10,000 ms
Temperature Drift (-10 °C < Tu < 50 °C) < 0.2 mm/K
Temperature Drift (Tu < -10 °C, Tu > 50 °C) < 0.4 mm/K
Temperature Range -25 ... 60 °C
Number of Switching Outputs 2
Switching Output Voltage Drop < 2.5 V
Switching Output/Switching Current 200 mA
Analog Output 0...10 V
Short Circuit Protection yes
Overload Protection yes
Lockable yes
Protection Class III
FDA Accession Number 0920382-000

Mechanical Data

Setting Method Menu (OLED)
Housing Material Plastic, ABS
Plastic, PC
Optic Cover Plastic, PMMA
Degree of Protection IP68
Connection M12 × 1; 4-pin
Weight 84 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 346.68 a

Output

Error Output yes
PNP NC yes
Analog Output yes

Adjustable parameters

Analog output 0...10 V
4...20 mA
Output Analog Output
Error Output
Push-pull
NPN
PNP
All other parameters can be found in the product documentation.

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf
Display brightness may decrease with age. This does not result in any impairment of the sensor function.

Table 1

Working Distance 0 m 10 m
Light Spot Diameter 5 mm < 20 mm

Connection Diagram

Ctrl. Panel

21 = Mode Button
60 = display

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
1 = Transmitter Diode 2 = Receiver Diode Screw M4 = 0.5 Nm

Reflector data

RF505 0.1 ... 10 m
RF508 0.1 ... 10 m
RF258 0.1 ... 10 m
ZRAF07K01 0.1 ... 10 m
ZRAF08K01 0.1 ... 10 m
ZRDF__K01 0 ... 10 m

Complementary Products

  • Analog Evaluation Unit AW02
  • Reflector, Reflector Foil
  • Set Protective Housing ZST-NN-02

Product Highlights

This area provides a deeper insight into this product world. All information about new product series as well as tutorials, templates and much more are combined here and are clearly prepared – tangible, understandable and traceable. Everything at a glance.
Product Comparison