FXTT004 Temperature Sensor with IO-Link

Usually ready to ship in 30 days after order is received.
weFlux² Temperature Sensors ensure precise temperature measurement of liquids and gases in closed piping systems. Either 2 switching outputs, 1 switching output and 1 analog output or one 2-wire analog output is available depending on settings and connection configuration. The outputs can be configured as desired via IO-Link in order to flexibly adapt the sensors to the respective application.

Sensor-specific data

Temperature Measurement Range -50 ... 150 °C
Setting Range -50 ... 150 °C
Medium Liquids, gases
Measuring error ± 0.5 °C
Resolution  > 11 bit
Response Time  < 2 s

Environmental conditions

Temperature of medium -50 ... 150 °C
Ambient temperature -25 ... 80 °C
Storage temperature -25 ... 80 °C
Pressure Resistance 100 bar
EMC DIN EN 61326-1
Shock Resistance IEC 60751
Vibration resistance IEC 60751

Electrical Data

2-wire supply power 12 ... 32 V DC
3-wire supply power 12 ... 32 V DC
Current Consumption (Ub = 24 V) < 15 mA
Number of Switching Outputs 2
Switching Output/Switching Current ± 100 mA
Switching Output Voltage Drop < 1.5 V DC
Analog Output 4...20 mA
Signal source Temperature
Short Circuit Protection yes
Reverse Polarity Protection yes
Protection Class III
Interface IO-Link V1.1

Mechanical Data

Setting Method IO-Link
Housing Material Stainless steel, V4A (1.4404/316L)
Material in contact with media Stainless steel, V4A (1.4404/316L)
Rubber, FKM
Rubber, FPM
Degree of Protection IP68/IP69K *
Connection M12 × 1; 4-pin
Process Connection Sealing cone M18 × 1,5
Process Connection Length (PCL) 232 mm
Probe Length (PL) 200 mm
Weight 317 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 1,198.4 a

Output

Analog Output yes
IO-Link yes
PNP NO yes

Adjustable parameters

Analog output 0...10 V
4...20 mA
Circuit NC
NC/NO
NO
Other parameters 2 switching points
Selectable measurement range
All other parameters can be found in the product documentation.

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf
* Certified by wenglor

Connection Diagram

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")

Complementary Products

  • IO-Link Master
  • Software
Initial start-up instructions
Operating instructions
Quick-start guide
Product description file
Product description file
IODD_FXTT0_V1.1.zip
Interface protocol
Interface protocol
Interface_Protocol_IO-Link_Parameter_Process_Data_FXTT0.pdf
Declarations of Conformity / Approvals
Product certificates
Product certificates
FXFF_IO-Link_V1.1_Manufacturer_declaration.pdf Fluid_sensors_food_safety_declaration.pdf
Product Comparison