text.skipToContent text.skipToNavigation

P1KH017 Reflex Sensor with Background Suppression

Usually ready to ship in 20 days after order is received.
The reflex sensor with background suppression works with laser light according to the angle measurement principle. It has a IO-Link interface with a data storage function as well as additional configuration and diagnostic options. The interface can also be used to configure the sensors (PNP/NPN, NC/NO, switching distance, error output), as well as for reading out switching statuses and distance values. The teach-in function also provides another configuration option. Two independent switching outputs can be used, for instance, to monitor minimum and maximum values of distances or fill levels and stack heights.

Optical Data

Range 120 mm
Setting Range 30 ... 120 mm
Switching Hysteresis  < 10 %
Light Source Laser (red)
Wavelength 680 nm
Service Life (T = +25 °C) 100,000 h
Laser Class (EN 60825-1) 1
Max. Ambient Light 10,000 Lux
Light Spot Diameter see Table 1

Electrical Data

Supply Voltage 15 ... 30 V DC
Supply Voltage with IO-Link 18 ... 30 V DC
Current Consumption (Ub = 24 V) < 15 mA
Switching Frequency 100 Hz
Switching Frequency (1 Switching Output) 1,000 Hz
Response Time 5 ms
Response time (1 switching output) 0.5 ms
Temperature Drift < 5 %
Temperature Range -40 ... 60 °C
Number of Switching Outputs 2
Switching Output Voltage Drop < 2 V
Switching Output/Switching Current 100 mA
Residual Current Switching Output < 50 µA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Lockable yes
Interface IO-Link V1.1
Data Storage yes
Protection Class III
FDA Accession Number 1710976-001

Mechanical Data

Setting Method Teach-In
Housing Material Plastic, ABS/PC
Degree of Protection IP67/IP68
Connection M8 × 1; 4-pin
Optic Cover Plastic, PMMA
Weight 6 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 1,480.59 a

Output

PNP NO yes
IO-Link yes

Adjustable parameters

Output Push-pull
NPN
PNP
Circuit NC
NC/NO
NO
Other parameters Off-delay
On-delay
Mode of operation
Hysteresis
Switching point
Emitted light
All other parameters can be found in the product documentation.

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf

Table 1

Detection Range 40 mm 80 mm 120 mm
Light Spot Diameter 2,5 mm 1,5 mm 1 mm

Connection Diagram

Switching Distance Deviation

Typical characteristic curve based on white, 90 % remission
Sr = Switching Distance
dSr = Switching Distance Change
black 6 % remission
grey 18 % remission

Ctrl. Panel

30 = Switching Status/Contamination Warning
68 = supply voltage indicator
06 = Teach Button
5a = Switching Status Indicator, A1
6a = Switching Status Indicator, A2

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
1 = Transmitter Diode 2 = Receiver Diode Screw M3 = 0,5 Nm

Complementary Products

  • IO-Link Master
  • Software
Initial start-up instructions
Operating instructions
Product description file
Product description file
IODD_P1KH017_V1.1.zip
Interface protocol
Interface protocol
Interface_Protocol_IO-Link_Parameter_Process_Data_P1KHxxx_High_End.pdf
Declarations of Conformity / Approvals
Product certificates
Product certificates
P1KE_P1KH_P1KK_P1KL_P1KT_IO-Link_V1.1_Manufacturer_declaration.pdf

Product Highlights

This area provides a deeper insight into this product world. All information about new product series as well as tutorials, templates and much more are combined here and are clearly prepared – tangible, understandable and traceable. Everything at a glance.
Product Comparison