text.skipToContent text.skipToNavigation

P1XD114 Fiber-optic amplifier

Usually ready to ship in 20 days after order is received.
These sensors work according to the energetic principle. Light is transmitted through one fiber-optic cable and received through the other. The amplifier can be adapted to a wide range of application requirements using the various plastic fiber-optic cables or fiber-optic cables with adapter no. 4. The display shows both the switching threshold and the currently received signal. Thanks to its intuitive setup, the sensor can be quickly configured using the buttons. Complex parameterizations are also easy to do using a mobile device and the wenglor weCon app or via IO-Link. All sensor information is provided via the IO-Link process data. The fiber-optic cable and sensor are installed without the use of tools.

Optical Data

Switching Hysteresis  < 15 %
Light Source Red Light
Service Life (T = +25 °C) > 100,000 h
Max. Ambient Light 10,000 Lux

Electrical Data

Supply Voltage 10 ... 30 V DC
Supply Voltage with IO-Link 18 ... 30 V DC
Current Consumption (Ub = 24 V) < 40 mA
Switching Frequency 7 kHz
Response Time 71 µs
On-/Off-Delay 0 ... 10,000 ms
Temperature Drift < 10 %
Temperature Range -25 ... 60 °C
Switching Output Voltage Drop < 2 V
Switching Output/Switching Current 100 mA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Teach Mode NT, MT, MT with dynamic readjustment, jump detection, DT, BT, WT
Baud Rate COM3
Interface IO-Link V1.1.3
Protection Class III

Mechanical Data

Setting Method NFC
Display
Housing Material Plastic, ABS
Plastic, PC
Plastic, PA
Degree of Protection IP50
Connection M8 × 1; 4-pin
DIN-Rail mounting 35 mm
Weight 190 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 640.47 a

Output

IO-Link yes
NPN NC, NPN NO yes

Adjustable parameters

Output Push-pull
NPN
PNP
Circuit inactive
Error output
NC
NC+NO
NO
Other parameters 2 switching points
Off-delay
On-delay
Dynamic readjustment
Error indicator
Error output
Filter
Hysteresis
Switching point
Emitted light
Sensor localization
Adjustable sensor mode
Teach mode

Standards and certificates

B_SYM_RoHS_01.pdf B_SYM_RoHS_01.pdf B_SYM_RoHS_01.pdf B_SYM_RoHS_01.pdf B_SYM_RoHS_01.pdf B_SYM_RoHS_01.pdf B_SYM_RoHS_01.pdf

Connection Diagram

Ctrl. Panel

06 = Teach Button
21 = Mode Button
24 = Plus Button
25 = Minus Button
5a = Switching Status Indicator, A1
60 = display
68 = supply voltage indicator
6a = Switching Status Indicator, A2

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
1 = Transmitter Diode 2 = Receiver Diode

Complementary Products

  • Plastic Fiber-Optic Cable
  • IO-Link Master
Initial start-up instructions
Operating instructions
Product description file
Product description file
wenglor-P1XD114-20240902-IODD1.1.zip
Declarations of Conformity / Approvals

Product Highlights

This area provides a deeper insight into this product world. All information about new product series as well as tutorials, templates and much more are combined here and are clearly prepared – tangible, understandable and traceable. Everything at a glance.
Product Comparison