P1PH306 Reflex Sensor with Background Suppression

Available from stock
The reflex sensor with background suppression works with blue light according to the angle measurement principle and is designed to detect objects against any background. The sensor always has the same switching distance, regardless of the color, shape and surface of the objects. The reflect sensor with blue light is specially designed for applications with dark shiny objects, such as when manufacturing solar wafers. The IO-Link interface can be used to configure the reflex sensors (PNP/NPN, NC/NO, switching distance), as well as for reading out switching statuses and distance values.

Optical Data

Range 400 mm
Setting Range 50 ... 400 mm
Switching Hysteresis  < 3 %
Light Source Blue Light
Service Life (T = +25 °C) 100,000 h
Risk Group (EN 62471) 1
Max. Ambient Light 10,000 Lux

Electrical Data

Supply Voltage 15 ... 30 V DC
Supply Voltage with IO-Link 18 ... 30 V DC
Current Consumption (Ub = 24 V) < 20 mA
Switching Frequency 800 Hz
Switching Frequency (interference-free mode) 500 Hz
Response time (interference-free mode) 1.5 ms
Response Time 1.25 ms
Temperature Drift < 5 %
Temperature Range -40 ... 60 °C
Switching Output Voltage Drop < 2 V
Switching Output/Switching Current 100 mA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Interface IO-Link V1.1
Protection Class III

Mechanical Data

Setting Method Potentiometer
Housing Material Plastic, ABS/PC
Degree of Protection IP67/IP68
Connection M12 × 1; 4-pin
Optic Cover Plastic, PMMA
Weight 33 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 917.7 a

Output

NPN NC, NPN NO yes
IO-Link yes

Adjustable parameters

Output Push-pull
NPN
PNP
Circuit NC
NO
inactive
Error output
NC+NO
Other parameters Off-delay
On-delay
Mode of operation
Hysteresis
Switching point
Emitted light
All other parameters can be found in the product documentation.

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf

Table 1

Detection Range 50 mm 200 mm 400 mm
Light Spot Diameter 11 mm 13 mm 14 mm

Connection Diagram

Switching Distance Deviation

Typical characteristic curve based on white, 90 % remission
Sr = Switching Distance
dSr = Switching Distance Change
black 6 % remission
grey 18 % remission

Ctrl. Panel

30 = Switching Status/Contamination Warning
05 = Switching Distance Adjuster
68 = supply voltage indicator

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
1 = Transmitter Diode 2 = Receiver Diode 3 = Wrench Size 7 Screw M4 = 0.5 Nm

Complementary Products

  • IO-Link Master
  • Software
  • Set Protective Housing Z1PS001
Initial start-up instructions
Operating instructions
Product description file
Product description file
IODD_P1PH306_V1.1.zip
Interface protocol
Interface protocol
Interface_Protocol_IO-Link_Parameter_Process_Data_P1PHxxx_el.pdf
Declarations of Conformity / Approvals
Product certificates
Product certificates
P1PE_P1PH_P1PK_P1PL_IO-Link_V1.1_Manufacturer_declaration.pdf

Product Highlights

This area provides a deeper insight into this product world. All information about new product series as well as tutorials, templates and much more are combined here and are clearly prepared – tangible, understandable and traceable. Everything at a glance.
Product Comparison