text.skipToContent text.skipToNavigation

OUM502C0002 Fiber-optic amplifier

Available from stock
These sensors are equipped for use with glass fiber optic cables but can be used with or without one. The transmitter and receiver are located in a single housing. The sensor evaluates transmitted light reflected back from the object and the output is switched as soon as an object passes the selected range. Bright objects reflect more light than dark objects, and can thus be recognized from greater distances.

Optical Data

Range 500 mm
Switching Hysteresis  < 10 %
Light Source Infrared Light
Wavelength 875 nm
Service Life (T = +25 °C) 100,000 h
Max. Ambient Light 10,000 Lux
Opening Angle 12 °

Electrical Data

Supply Voltage 18 ... 30 V DC
Current Consumption (Ub = 24 V) < 30 mA
Switching Frequency 2.5 kHz
Response Time 200 µs
On-/Off-Delay 0 ... 60 s
Temperature Drift < 10 %
Temperature Range -25 ... 60 °C
Switching Output Voltage Drop < 2.5 V
PNP Switching Output/Switching Current 100 mA
Residual Current Switching Output < 50 µA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Teach Mode NT, MT
Interface IO-Link V1.0
Protection Class III

Mechanical Data

Setting Method Teach-In
Housing Material Plastic, PBT
Full Encapsulation yes
Degree of Protection IP67
Connection M12 × 1; 4-pin
Weight 66 g

Output

IO-Link yes
PNP NO yes

Adjustable parameters

Circuit NC
NC/NO
NO
Other parameters Off-delay
On-delay

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf

Connection Diagram

Ctrl. Panel

30 = Switching Status/Contamination Warning
06 = Teach Button

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
1 = Transmitter Diode 2 = Receiver Diode Screw M4 = 1 Nm

Complementary Products

  • Glass Fiber-Optic Cable
  • IO-Link Master
  • PNP-NPN Converter BG2V1P-N-2M
  • Software
Initial start-up instructions
Operating instructions
Product Flyers
Product description file
Product description file
IODD_OUM502C0002_V1.0.1.zip
Interface protocol
Interface protocol
Interface_Protocol_IO-Link_Parameter_Process_Data_OLM_OUM_OTM.pdf
Declarations of Conformity / Approvals
Product Comparison