text.skipToContent text.skipToNavigation

I18G002 Inductive Sensor with Full-Metal Housing

Available from stock
The inductive sensors with full-metal housing are suitable for harsh ambient conditions and washdown areas thanks to the 316L stainless steel housing. The sensors with full-metal housing impress with their easy installation and reliable switching behavior. In addition to error-free operation of several sensors in a very small space, the new generation also provides the possibility of detecting system errors before it’s too late thanks to ASIC, IO-Link interface and wenglor weproTec.

Inductive Data

Switching Distance 10 mm
Correction Factors Stainless Steel V2A/CuZn/Al 0,94/0,35/0,31
Mounting Flush
Mounting A/B/C/D in mm 0/35/30/0
Mounting A/B/C/D (V2A) in mm 0/25/30/0
Mounting B1 in mm 0...10
Installation B1 (V2A) in mm 0...8
Switching Hysteresis < 10 %

Electrical Data

Supply Voltage 10 ... 30 V DC
Supply Voltage with IO-Link 18 ... 30 V DC
Current Consumption (Ub = 24 V) < 15 mA
Switching Frequency 386 Hz
Temperature Drift < 10 %
Temperature Range -25 ... 70 °C
Switching Output Voltage Drop < 1 V
Switching Output/Switching Current 100 mA
Residual Current Switching Output < 100 µA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Protection Class III
Interface IO-Link V1.1

Mechanical Data

Housing Material Stainless steel, V4A (1.4404 / 316L)
Sensing face Stainless steel, V4A
Full Encapsulation yes
Degree of Protection IP67/IP68/IP69K *
Connection M12 × 1; 4-pin
Torque max. 45 Nm
Pressure Resistance Sensor Area 15 bar
EX II 3D Ex tc IIIC T90° Dc yes
EX II 3G Ex ic IIC T5 Gc yes
Weight 40 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 3,706.54 a

General Data

Packaging unit 1 Piece

Output

PNP NC, PNP NO yes

Adjustable parameters

Output NPN
PNP
Circuit NC
NO
inactive
Error output
NC+NO

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf
* For applications in areas with explosive atmospheres: IP67

Connection Diagram

Mounting

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
B_SYM_SCHLUESSEL_24.pdf Wrench Size

Complementary Products

  • IO-Link Master
Initial start-up instructions
Operating instructions
System solution
Product description file
Product description file
wenglor-I18G002-20231030-IODD1.1.zip
Interface protocol
Interface protocol
Interface_Protocol_IO-Link_Parameter_Process_Data_I18G00x.pdf
Declarations of Conformity / Approvals

Product Highlights

This area provides a deeper insight into this product world. All information about new product series as well as tutorials, templates and much more are combined here and are clearly prepared – tangible, understandable and traceable. Everything at a glance.
Product Comparison