text.skipToContent text.skipToNavigation

FFAP277 Pressure Sensor

Usually ready to ship in 30 days after order is received.
UniBar pressure sensors measure the relative pressure in closed systems of any medium in the range -1...600 bar. UniBar pressure sensors are very easy to use thanks to the integrated display. The highly visible switching status display enables the rapid localization of affected sensors for maintenance processes.

Sensor-specific data

Measuring Range 0 ... 40 bar
Measurement Type relative
Maximum overload pressure 80 bar
Bursting pressure 160 bar
Setting Range 4 ... 100 %
Medium Liquids, gases
Switching Hysteresis 2 %
Measuring error < ± 0.5 %
Temperature Drift 0.025 %/K

Environmental conditions

Temperature of medium -25 ... 80 °C
Ambient temperature -25 ... 80 °C
EMC DIN EN 61326-2-3
Shock resistance per DIN IEC 68-2-27 30 g / 11 ms
Vibration resistance per DIN IEC 60068-2-6 20 g (10...2000 Hz)

Electrical Data

Supply Voltage 16 ... 32 V DC
Current Consumption (Ub = 24 V) < 60 mA
Number of Switching Outputs 2
Response Time 30 ms
Switching Output/Switching Current < 250 mA
Switching Output Voltage Drop < 2 V
Resolution 10 bit
Short Circuit Protection yes
Reverse Polarity Protection yes
Protection Class III

Mechanical Data

Setting Method Menu
Housing Material Plastic, PBT
Plastic, PC
Material Control Panel Polyester
Material in contact with media Stainless steel, V4A (1.4404 / 316L)
Stainless steel, V4A (1.4435/316L)
Rubber, FKM
Degree of Protection IP67 *
Connection M12 × 1; 4-pin
Process Connection G 1/2"
Weight 270 g

Output

PNP NO yes

Adjustable parameters

Circuit NC
NC/NO
NO
Other parameters 2 switching points
All other parameters can be found in the product documentation.

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf
* Certified by wenglor

Connection Diagram

Ctrl. Panel

01 = Switching Status Indicator
60 = display
20 = Enter key
22 = Up key
99 = Right button

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
1 = Rotatable relative to housing at 340° B_SYM_SCHLUESSEL_27.pdf Wrench Size
Initial start-up instructions
Operating instructions
General instructions
General instructions
Note_Menue_2x_switch_Pressure.pdf
Declarations of Conformity / Approvals
Product Comparison