text.skipToContent text.skipToNavigation

FXPL001 Fill-level Sensor with IO-Link

Available from stock
LevelTech fill-level sensors work in accordance with the innovative frequency sweep principle. With the help of this functional principle, the sensors detect any desired medium on the basis of the measured resonant frequency. With their two adjustable switching outputs, the sensors are capable of differentiating between foam and liquid or two different media. Sensor parameters, as well as filter and output functions, can be individually configured via IO-Link. The stainless steel housing is FDA compliant and can be installed in the tightest of spaces thanks to its compact design.

Sensor-specific data

Measuring principle Frequency sweep
Measuring Range > DK*** 1.5
Medium Liquids, granulate, powder
Response Time 0.04 s

Environmental conditions

Media temperature TM (TU < 50 °C) -40 ... 115 °C**
Media temperature TM brief (TU < 50 °C, t < 1 h) -40 ... 130 °C
Ambient temperature -40 ... 85 °C
Storage temperature -40 ... 85 °C
Pressure Resistance 100 bar
EMC DIN EN 61326 *
Vibration resistance per DIN IEC 60068-2-6 1,6 mm p-p (2...25 Hz), 4 g (25...100 Hz)

Electrical Data

Supply Voltage 8 ... 36 V DC
Current Consumption (Ub = 24 V) < 35 mA
Number of Switching Outputs 2
Power-up Time < 3 s
Switching Output/Switching Current 100 mA
Switching Output Voltage Drop < 0.7 V
Signal source Change of medium
Leakage Current < 100 µA
Short Circuit Protection yes
Reverse Polarity Protection yes
Interface IO-Link V1.1

Mechanical Data

Setting Method Teach-in/IO-Link
Housing Material Stainless steel, V4A (1.4404/316L)
Plastic, PC
Material in contact with media Plastic, PEEK
Degree of Protection IP67/IP69K
Connection M12 × 1; 4-pin
Connector Plug Material Polycarbonate
Process Connection G 1/2"
Weight 71 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 686 a

Function

Attenuation (adjustable) 0 ... 10 s
Selective fill-level measurement yes

Output

IO-Link yes
Push-Pull yes

Adjustable parameters

Output Push-pull
NPN
PNP
Circuit NC
NC/NO
NO
Other parameters 2 switching points
All other parameters can be found in the product documentation.

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf
* mounted in closed metal tank
** TM= temperature of medium; TU= ambient temperature
*** The relative dielectric constant of the medium to be detected must be greater than 1.5. (DC = dielectric constant)

Connection Diagram

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")

Complementary Products

  • IO-Link Master
  • Software
Initial start-up instructions
Operating instructions
Quick-start guide
Product description file
Product description file
IODD_FXxL0_V1.1.zip
Interface protocol
Interface protocol
Interface_Protocol_IO-Link_Parameter_Process_Data_FXxL0xx.pdf
Declarations of Conformity / Approvals
Product certificates
Product certificates
FXxL_IO-Link_V1.1_Manufacturer_declaration.pdf Fluid_sensors_food_safety_declaration.pdf
Product Comparison