2D/3D Profile Sensors project a laser line onto the object to be detected and generate an accurate, linearized height profile with an internal camera which is set up at a triangulation angle. Thanks to its uniform, open interface, the weCat3D series can be incorporated by means of the DLL program library or the GigE Vision standard without an additional control unit. Alternatively, wenglor offers its own software packages for implementing your application.

Optical Data

Working range Z 83 ... 213 mm
Measuring range Z 130 mm
Measuring range X 50 ... 110 mm
Linearity Deviation 55 µm
Resolution Z 3.2 ... 14 µm
Resolution X 26 ... 55 µm
Light Source Laser, UV/red
Wavelength 375 / 660 nm
Service Life (T = +25 °C) 20,000 h
Laser Class (EN 60825-1) 2

Environmental conditions

Ambient temperature 0 ... 45 °C
Storage temperature -20 ... 70 °C
Max. Ambient Light 5,000 Lux
EMC DIN EN 61000-6-2; 61000-6-4
Shock resistance per DIN IEC 68-2-27 30 g / 11 ms
Vibration resistance per DIN IEC 60068-2-6 6 g (10...55 Hz)

Electrical Data

Supply Voltage 18 ... 30 V DC
Current Consumption (Ub = 24 V) 1,500 mA
Measuring Rate 175 ... 6,000 /s
Subsampling 350 ... 6,000 /s
Inputs/Outputs 4
Switching Output Voltage Drop < 1.5 V
Switching Output/Switching Current 100 mA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Interface Ethernet TCP/IP
Baud Rate 100/1000 Mbit/s
Protection Class III

Mechanical Data

Housing Material Aluminum, anodised
Degree of Protection IP67
Connection M12 × 1; 12-pin
Type of Connection Ethernet M12 × 1; 8-pin
Optic Cover Glass
Weight 727 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 131.74 a

General Data

Web server yes

Output

Configurable as PNP/NPN/Push-Pull yes
Switchable to NC/NO yes
Push-Pull yes

Adjustable parameters

Output Push-pull
NPN
PNP
Circuit NC
NC/NO
NO
All other parameters can be found in the product documentation.

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf

Connection Diagram

Measuring field X, Z

Z = Working distance
X = Measuring Range

Ctrl. Panel

20 = Enter key
22 = Up key
23 = Down key
60 = display
4a = User LED
68 = supply voltage indicator
78 = Module status
85 = Link/Act LED

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")

Complementary Products

  • Control Unit
  • EHSS001 Switch
  • Cooling Unit ZLWK002
  • Protective Screen Retainer ZLWS002
  • Software
  • Machine Vision Controller MVC
Operating instructions
General instructions
General instructions
DNNF020.pdf
Soft- and Firmware
Soft- and Firmware
Example_Rockwell_TCP_UDP_uniVision_1.0.0.zip Example_TIA_TCP_UDP_uniVision_1.0.0.zip Example_TwinCAT3_TCP_UDP_uniVision_1.0.0.zip Firmware_weCat3D_1.3.1.zip Firmware_weCat3D_2.3.0.zip SDK_Windows_LabView_weCat3D_1.2.0.zip Software_VisionApp_Demo_3D_3.1.0.zip Software_uniVision_2.6.1.exe Software_weCat3D_SDK_Windows_Linux_1.7.0.zip weCat3D_GigE_Interface_Windows_X64_2.2.1.zip weCat3D_Obsolet_GigE_Interface_Windows_X64_V1_2_0.zip
Interface protocol
Interface protocol
Interface_Protocol_DNNFxxx_LIMA.pdf Interface_Protocol_DNNFxxx_TCP_UDP.pdf
Declarations of Conformity / Approvals
Product certificates
Product certificates
OPT3013_Laser_Safety_Certificate.pdf

Product Highlights

This area provides a deeper insight into this product world. All information about new product series as well as tutorials, templates and much more are combined here and are clearly prepared – tangible, understandable and traceable. Everything at a glance.
Product Comparison